HW020: RHH-LS/RHW-LS, LSZH LifeGuard™ Building Wire 600 V UL, VW-1 Low Smoke Zero Halogen Insulation/Jacket

*Product images are for illustrative purposes only and may differ from the actual product.

HW020: RHH-LS/RHW-LS, LSZH LifeGuard™ Building Wire 600 V UL, VW-1 Low Smoke Zero Halogen Insulation/Jacket


Please select all above options before adding to cart.

Construction
Category Insulation Description Thermoset, sunlight-resistant and flame-retardant Low Smoke Zero Halogen polyolefin per ICEA S-95-658, UL Standard 44 and UL Standard 1685
Category Conductor Description Tin coated soft annealed copper per ASTM B-33, Class K, G, or I flexible stranding per ASTM B-172, B-173, B-174
Category Description Cable tray rated on sizes 1/0 AWG and larger Sunlight-resistant Tinned conductor provides ease of termination and added protection in caustic environments Very low smoke production when burned
Applications LifeGuard™ Low Smoke Zero Halogen cable is for use in harsh environments in a broad range of commercial, industrial and utility applications where reliability and maximum performance is required. It is highly flame retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™cable is ideal for applications where a high degree of safety and equipment protection is required. It is rated for use at 75°C in wet locations and 90°C in dry locations and approved for installation in conduit, duct, cable tray when CT rated; or other approved raceways.
Category Standards NEMA WC-70
  • LifeGuard™ Low Smoke Zero Halogen cable is for use in harsh environments in a broad range of commercial, industrial and utility applications where reliability and maximum performance is required. It is highly flame retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™cable is ideal for applications where a high degree of safety and equipment protection is required. It is rated for use at 75°C in wet locations and 90°C in dry locations and approved for installation in conduit, duct, cable tray when CT rated; or other approved raceways.
  • NEMA WC-70

Questions & Answers

Ask a Question

Part Number Table

Part # Houston Wire & Cable Gauge Conductors Stranding Outside Diameter Inches Insulation Thickness Material Weight (Lbs./M')
HW02001401 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 14 1 41 0.16 45 27
HW02001201 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 12 1 65 0.18 45 36
HW02001001 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 10 1 49 0.2 45 50
HW02000801 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 8 1 49 0.27 60 82
HW02000601 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 6 1 63 0.33 60 117
HW02000401 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 4 1 105 0.39 60 27
HW02000201 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 2 1 161 0.45 60 260
HW02010101 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 1/0 1 26 0.58 80 423
HW02020101 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 2/0 1 342 0.63 80 117
HW02040101 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 4/0 1 532 0.74 80 532
HW02035001 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 350 1 882 0.95 95 1302
HW02050001 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 500 1 1225 1.09 95 1831
HW02075001 https://www.omnicable.com/docs/default-source/default-document-library/hw020.pdf 750 1 1862 1.33 110 2752