Medium Voltage

*Product images are for illustrative purposes only and may differ from the actual product.

15kV - EPR Insulation, PVC Jacket

Single Conductor - EPR Insulation - PVC Jacket
15 kV, EPR/Copper Tape Shield
UL Type MV-105
133% Insulation Levels

x

Please select all above options before adding to cart.
Construction
Category Conductor Description 2 AWG thru 1000 kcmil 1350 aluminum compact Class B strand
Extruded Strand Shield Extruded thermoset semi-conducting stress-control layer over conductor
Category Insulation Description Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers
Extruded Insulation Shield Thermoset semi-conducting polymeric layer free stripping from insulation
Metallic Shield 5 mil annealed copper tape with an overlap of 25%
Category Jacket Description Low-friction, lead-free, flame-retardant, moisture and sunlight-resistant Polyvinyl Chloride (PVC)
  • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications
  • For use in wet or dry locations when installed in accordance with NEC
  • For use in aerial, conduit, open tray and underground duct installations
  • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5)
  • National Electrical Code (NEC)
  • UL 1072
  • ICEA S-93-639/NEMA WC74
  • ICEA S-97-682
  • AEIC CS8
  • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501
  • IEEE 1202 (70,000 BTU/hr)/CSA FT4
  • EPA 40 CFR, Part 261 for leachable lead content per TCLP method
  • OSHA Acceptable
  • RoHS Compliant

Questions & Answers

Ask a Question

Part Number Table

Part # Gauge Conductor Diameter Insulation Diameter Min Insulation Diameter Max Jacket Thickness Outside Diameter Inches Material Weight (Lbs./M')
MVA30201 2 .270" .710" .800" 0.08 0.99 488
MVA30101 1 .310" .745" .830" 0.08 1.02 523
MVA31/001 1/0 .340" .780" .865" 0.08 1.06 575
MVA32/001 2/0 .380" .820" .905" 0.08 1.089 627
MVA33/001 3/0 .430" .865" .955" 0.08 1.134 690
MVA34/001 4/0 .480" .920" 1.005" 0.08 1.184 758
MVA325001 250 .530" .970" 1.06" 0.08 1.242 837
MVA335001 350 .620" 1.07" 1.155" 0.08 1.337 994
MVA350001 500 .740" 1.19" 1.275" 0.08 1.457 1217
MVA375001 750 .910" 1.37" 1.46" 0.08 1.639 1583
MVA3100001 1000 1.06" 1.52" 1.61" 0.11 1.852 2026

Note: The data shown are approximate and subject to standard industry and manufacturer tolerances